Description
Cabinet
Stainless steel panels resist wear and corrosion. Durable Satin Finish helps hide water spots and fingerprints.
Cooler Top
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
Bubbler
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
Automatic Stream Height Regulator
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
Inlet Strainer
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
Temperature Control
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F.
Storage Tank
Non-pressurized stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
Refrigeration System
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and self-lubricated fan cools copper/aluminum condenser. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
Ventilation
Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall.
Suggested Specifications
Shall be floor-standing explosion proof type cooler for extreme conditions, including areas where excessive heat, dust and hazardous atmospheres are present. Shall deliver 8.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound-building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, non-pressurized tank with totally encapsulated insulation and be controlled by positive sensing thermostat. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
Features and Benefits
- U.L. listed for hazardous locations
- Durable satin finish stainless steel only
Warranty Info
LIMITED PRODUCT WARRANTY* FIRST YEAR – - The Manufacturer warrants every water cooler, packaged water chiller, fountain and accessory to be free from defects in material and workmanship under normal use for (1) year from date of installation or eighteen (18) months from date of shipment from the factory, whichever occurs first. SECOND THROUGH FIFTH YEARS – The Manufacturer warrants the compressor and hermetically sealed refrigeration system, including cooling coils or tank assembly when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship under normal use for an additional four (4) years from the end of the one (1) year period described above. Packaged water chillers are not subject to the additional four (4) year warranty when used in chilled water commercial/industrial applications other than for potable water. INSTALLATION AND OPERATION – The foregoing Limited Warranty applies only when the product is installed and operated in accordance with the Manufacturer’s written instructions included with each unit. These products are designed to operate on 20 psi to 105 psi supply line pressure. Nonfiltered Bi-level units require a minimum of 40 psi supply line pressure to ensure adequate stream height from each bubbler when activated simultaneously. Bi-level filtered models, regardless of supply line pressure, cannot provide adequate stream height from each bubbler when activated simultaneously. It does not apply to products which, on examination by the Manufacturer, or its agent, are found to have been subjected to accident, alteration, abuse, misuse, misapplications, corrosive type atmospheres, or abnormal use. OWNER’S OBLIGATIONS – The owner has the obligation and responsibility to diagnose and/or make minor adjustments and to reimburse the authorized service center or the Manufacturer for any other repair not covered by the terms of this limited Warranty. Any appearance imperfections are to be noted at time of installation, and the installer or the supplier notified without delay. In the case of products located within the United States or Canada, the owner also has the obligation and responsibility to return the complete unit to the closest authorized service center or to the factory repair department. In the case of products located outside the United States or Canada, the owner is to return any part for which replacement is sought to the closest authorized service center or to the factory repair department. MANUFACTURER’S OBLIGATIONS – When the product is located within the United States or Canada, the Manufacturer’s obligation under this Limited Warranty is limited to the labor and parts to repair or replace any part which is expressly covered by this Limited Warranty at one of its authorized service centers or at its factory repair department. The Manufacturer’s obligation also includes cost of outbound freight (but not express freight) of the part or parts from an authorized service center or the factory repair department, but only if the Manufacturer determines that the part or parts, and the purported defect or defects are covered by this Limited Warranty. When the product is located outside the United States or Canada, the Manufacturer’s obligation under this Limited Warranty is limited to providing a replacement part for any part expressly covered by this Limited Warranty which upon examination by the Manufacturer or his agent, is found to be defective, but does not include any obligation to provide labor or to pay labor costs incurred in connection with the replacement. The Manufacturer’s obligations also includes cost of outbound freight (but not express freight) of the part or parts from the factory repair department to (but not beyond) the port in the United States from which the part or parts are shipped to their ultimate destination, but only if the Manufacturer determines that the part or parts, and the purported defect or defects, are covered by this Limited Warranty. WHAT WARRANTY DOES NOT COVER – This Limited Warranty does not include payment for any field labor to provide for normal maintenance including adjustments such as water stream height, water temperature or electric eye sensitivity. The water system and regulating valve are not covered by this Limited Warranty if they become inoperative due to liming, sand or similar residue. This Limited Warranty is voided if repairs are made by an unauthorized party or the serial number data plate is removed or defaced. Normal deterioration of finish due to use and exposure is not covered by this Limited Warranty. The Manufacturer is not liable for repairs, whether cosmetic or structural, to walls where cooler and packaged water coolers are built into the wall. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this water cooler to supply line pressures lower than 20 psi or higher than 105 psi is not covered by this warranty. PERSONS ENTITLED TO BENEFIT OF WARRANTY – This Limited Warranty is applicable only to (i) purchasers who purchase the product for resale in the ordinary course of business, and (ii) the first person who purchases the product other than resale. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, EXPRESSED OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. EXCEPT AS EXPRESSLY PROVIDED HEREIN, THE MANUFACTURER MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, ARISING BY LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, TO ANY PERSON. THIS WARRANTY MAY NOT BE ALTERED, VARIED, OR EXTENDED, EXCEPT BY A WRITTEN INSTRUMENT EXECUTED BY THE MANUFACTURER. THE REMEDY OF REPAIR OR, WHERE APPLICABLE, REPLACEMENT AS PROVIDED UNDER THIS LIMITED WARRANTY IS EXCLUSIVE. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES TO ANY PERSON, WHETHER OR NOT OCCASIONED BY NEGLIGENCE OF THE MANUFACTURER, INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF USE, COSTS OR SUBSTITUTION, PROPERTY DAMAGE, OR OTHER MONETARY LOSS. This Limited Warranty gives specific legal rights and in some states of the United States there may be other rights which vary from state to state.
Manufacturer Info
Halsey Taylor offers outdoor water coolers, water coolers for schools, parks and shopping centers, floor-mounted and wall-mounted coolers, and fountains in a variety of shapes and styles. Our durable and attractive finishes further reflect our concern for our products appearance, as well as their ability to withstand the test of time.
Kully Item # | 106804 |
---|---|
Manufacturer | Halsey Taylor |
Model # | XP8W-Q |
Gooseneck Glass Filler | None |
Mounting Location | Floor Mounted |
Refrigerated | Yes |
Water Cooling Capacity | 8 GPH |
Finish | Stainless Steel |
Documents
Guide (165.11 KB)Write Your Own Review
Questions:
-
0voteA:
The Halsey Taylor XPSW-Q Explosion Proof Water Cooler (Part #106804) is not available in 220 VAC, 50 hz.
If you have any other questions our experts are here to help! Call or text 800-518-5388Posted by Kully Supply on Tuesday, March 28, 2017
-
0voteA: The Halsey Taylor XPSW-Q Explosion Proof Water Cooler (Part #106804) is not available in 220 VAC, 50 hz. If you have any other questions our experts are here to help! Call or text 800-518-5388Posted by Kully Supply on Thursday, February 9, 2017